Top Quality Single Phase To Three Phase Frequency Inverter - High Protection Universal Vector Inverter XCD-E7000 – LINGSHIDA Detail:
Features
Design features
Design features
1. Using 32-bit motor dedicated CPU, which has high-precision frequency output, and resolution up to 0.01Hz.
2. Comes with simple PLC and PID control functions.
3. Built-in RS485 communication interface, adopting international standard MODBUS bus control protocol.
4. With vector control mode and V/F control mode, it is suitable for various working conditions.
5. Low-speed rated torque output is 0.2Hz, and 150% rated torque can be output at startup.
6. With automatic voltage adjustment, frequency tracking starts when instantaneous stop.
7. With multi-speed control function, the carrier frequency is adjustable.
8. With multiple fault protection functions in conditions such as overvoltage, undervoltage, overheating, low temperature, overcurrent, overload, lack and etc.
9. Voice boot guidance and troubleshooting functions are optional
10. The protection grade is IP65, which can adapt to various harsh environments.
11. The all-aluminum casing design has good heat dissipation effect and better product stability.
Model Table
Product installation size
Product Structure
Technical Parameters
Model Table
Voltage level |
Model |
Rated Capacity |
Output Current |
Adapted motor |
A fixed way |
|
KW |
HP |
|||||
Single-phase AC110V |
XCD- E7100-0.4K |
0.4 |
4.5 |
0.4 |
0.5 |
Wall-mounted |
XCD- E7100-0.75K |
0.75 |
8.2 |
0.75 |
1 |
Wall-mounted |
|
XCD- E7100-1.5K |
1.5 |
16 |
1.5 |
2 |
Wall-mounted |
|
XCD- E7100-2.2K |
2.2 |
23.5 |
2.2 |
3 |
Wall-mounted |
|
XCD- E7100-3.0K |
3.0 |
32 |
3.0 |
4 |
Wall-mounted |
|
Single-phase AC220V |
XCD- E7200-0.75K |
0.75 |
4.8 |
0.75 |
1 |
Wall-mounted |
XCD- E7200-1.5K |
1.5 |
7.5 |
1.5 |
2 |
Wall-mounted |
|
XCD- E7200-2.2K |
2.2 |
11 |
2.2 |
3 |
Wall-mounted |
|
XCD- E7200-3.7K |
3.7 |
17.5 |
3.7 |
5 |
Wall-mounted |
|
XCD- E7200-5.5K |
5.5 |
22.5 |
5.5 |
8 |
Wall-mounted |
|
XCD- E7200-7.5K |
7.5 |
30 |
7.5 |
10 |
Wall-mounted |
|
Three-phase AC380V |
XCD- E7400-0.75K |
0.75 |
2.5 |
0.75 |
1 |
Wall-mounted |
XCD- E7400-1.5K |
1.5 |
3.8 |
1.5 |
2 |
Wall-mounted |
|
XCD- E7400-2.2K |
2.2 |
5.1 |
2.2 |
3 |
Wall-mounted |
|
XCD- E7400-3.7K |
3.7 |
9.0 |
3.7 |
5 |
Wall-mounted |
|
XCD- E7400-5.5K |
5.5 |
13 |
5.5 |
8 |
Wall-mounted |
|
XCD- E7400-7.5K |
7.5 |
17 |
7.5 |
10 |
Wall-mounted |
|
XCD- E7400-11K |
11 |
25 |
11 |
15 |
Wall-mounted |
|
XCD- E7400-15K |
15 |
32 |
15 |
20 |
Wall-mounted |
Product installation size
Inverter model specifications | Input voltage | D(mm) | D1(mm) | L(mm) | L1(mm) | K(mm) | Screw specifications |
XCD-E7000-0.75KW-15KW | 380V | 166.3 | 248 | 148 | 235 | 188 | M6 |
Product Structure
Technical Parameters
Input voltage range |
110V/220V/380V±15% |
Input frequency range |
50~60Hz |
Output voltage range |
0V~rated input voltage |
Power range |
0~400Hz |
Carrier frequency |
1.5K~16.0KHz |
Power range |
0.4~15.0KW |
communication method |
Support RS-485 serial communication |
Protection level |
IP67 |
Overload capacity |
120% motor rated current for 5 minutes 150% motor rated current for 5 seconds |
||
Programmable analog input and output |
0~10V analog voltage input 0~20mA analog current input |
||
Digital input and output |
3 multi-function terminal inputs, 1 programmable relay output |
||
Simple PLC, multi-speed control function |
Realize up to 8 speeds running through the built-in PLC or control terminal |
Product Application
XCD-E7000 product application industry:
Papermaking, food, fan, water pump, textile, printing, pharmaceutical, copper, printing and dyeing, packaging, woodworking machinery and other industries
Tips
Handling Skills of Frequency Inverter Undervoltage
In order to protect the frequency inverter, when the bus voltage is too low, the frequency inverter will report an undervoltage fault and block the frequency inverter’s pulse output. This is an important and necessary method to protect the frequency inverter components from damage. This fault cannot be shielded either.
There is a bus voltage check mechanism inside the frequency inverter. When the measured value of the bus voltage is lower than a certain threshold, the frequency inverter will report an undervoltage fault.
There are many reasons for the undervoltage of the DC bus, which should be analyzed according to the actual situation. If you find the right root cause and then prescribe the right medicine, it can usually be solved.
1. The first is the influence from the incoming line voltage.
2. The second is the influence from the output end, that is, the inverter side.
3. Finally, there is a hardware problem.
Product Application
XCD-E7000 product application industry:
Processing centers, large complete sets of equipment, plastic machinery, textiles, printing, copper materials, printing and dyeing, packaging, woodworking machinery and other industries
Product detail pictures:
Related Product Guide:
Our firm since its inception, normally regards item top quality as company life, constantly make improvements to generation technology, improve product excellent and repeatedly strengthen organization total good quality management, in strict accordance with the national standard ISO 9001:2000 for Top Quality Single Phase To Three Phase Frequency Inverter - High Protection Universal Vector Inverter XCD-E7000 – LINGSHIDA, The product will supply to all over the world, such as: Melbourne, Slovenia, Canada, Our market share of our products and solutions has greatly increased yearly. If you are interested in any of our products or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future. We've been looking forward to your inquiry and order.
By Jeff Wolfe from St. Petersburg - 2017.09.09 10:18
Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
By Queena from Italy - 2017.09.22 11:32