Good Quality Vfd Drive Price - High Protection Universal Vector Inverter XCD-E7000 – LINGSHIDA Detail:
Features
Design features
Design features
1. Using 32-bit motor dedicated CPU, which has high-precision frequency output, and resolution up to 0.01Hz.
2. Comes with simple PLC and PID control functions.
3. Built-in RS485 communication interface, adopting international standard MODBUS bus control protocol.
4. With vector control mode and V/F control mode, it is suitable for various working conditions.
5. Low-speed rated torque output is 0.2Hz, and 150% rated torque can be output at startup.
6. With automatic voltage adjustment, frequency tracking starts when instantaneous stop.
7. With multi-speed control function, the carrier frequency is adjustable.
8. With multiple fault protection functions in conditions such as overvoltage, undervoltage, overheating, low temperature, overcurrent, overload, lack and etc.
9. Voice boot guidance and troubleshooting functions are optional
10. The protection grade is IP65, which can adapt to various harsh environments.
11. The all-aluminum casing design has good heat dissipation effect and better product stability.
Model Table
Product installation size
Product Structure
Technical Parameters
Model Table
Voltage level |
Model |
Rated Capacity |
Output Current |
Adapted motor |
A fixed way |
|
KW |
HP |
|||||
Single-phase AC110V |
XCD- E7100-0.4K |
0.4 |
4.5 |
0.4 |
0.5 |
Wall-mounted |
XCD- E7100-0.75K |
0.75 |
8.2 |
0.75 |
1 |
Wall-mounted |
|
XCD- E7100-1.5K |
1.5 |
16 |
1.5 |
2 |
Wall-mounted |
|
XCD- E7100-2.2K |
2.2 |
23.5 |
2.2 |
3 |
Wall-mounted |
|
XCD- E7100-3.0K |
3.0 |
32 |
3.0 |
4 |
Wall-mounted |
|
Single-phase AC220V |
XCD- E7200-0.75K |
0.75 |
4.8 |
0.75 |
1 |
Wall-mounted |
XCD- E7200-1.5K |
1.5 |
7.5 |
1.5 |
2 |
Wall-mounted |
|
XCD- E7200-2.2K |
2.2 |
11 |
2.2 |
3 |
Wall-mounted |
|
XCD- E7200-3.7K |
3.7 |
17.5 |
3.7 |
5 |
Wall-mounted |
|
XCD- E7200-5.5K |
5.5 |
22.5 |
5.5 |
8 |
Wall-mounted |
|
XCD- E7200-7.5K |
7.5 |
30 |
7.5 |
10 |
Wall-mounted |
|
Three-phase AC380V |
XCD- E7400-0.75K |
0.75 |
2.5 |
0.75 |
1 |
Wall-mounted |
XCD- E7400-1.5K |
1.5 |
3.8 |
1.5 |
2 |
Wall-mounted |
|
XCD- E7400-2.2K |
2.2 |
5.1 |
2.2 |
3 |
Wall-mounted |
|
XCD- E7400-3.7K |
3.7 |
9.0 |
3.7 |
5 |
Wall-mounted |
|
XCD- E7400-5.5K |
5.5 |
13 |
5.5 |
8 |
Wall-mounted |
|
XCD- E7400-7.5K |
7.5 |
17 |
7.5 |
10 |
Wall-mounted |
|
XCD- E7400-11K |
11 |
25 |
11 |
15 |
Wall-mounted |
|
XCD- E7400-15K |
15 |
32 |
15 |
20 |
Wall-mounted |
Product installation size
Inverter model specifications | Input voltage | D(mm) | D1(mm) | L(mm) | L1(mm) | K(mm) | Screw specifications |
XCD-E7000-0.75KW-15KW | 380V | 166.3 | 248 | 148 | 235 | 188 | M6 |
Product Structure
Technical Parameters
Input voltage range |
110V/220V/380V±15% |
Input frequency range |
50~60Hz |
Output voltage range |
0V~rated input voltage |
Power range |
0~400Hz |
Carrier frequency |
1.5K~16.0KHz |
Power range |
0.4~15.0KW |
communication method |
Support RS-485 serial communication |
Protection level |
IP67 |
Overload capacity |
120% motor rated current for 5 minutes 150% motor rated current for 5 seconds |
||
Programmable analog input and output |
0~10V analog voltage input 0~20mA analog current input |
||
Digital input and output |
3 multi-function terminal inputs, 1 programmable relay output |
||
Simple PLC, multi-speed control function |
Realize up to 8 speeds running through the built-in PLC or control terminal |
Product Application
XCD-E7000 product application industry:
Papermaking, food, fan, water pump, textile, printing, pharmaceutical, copper, printing and dyeing, packaging, woodworking machinery and other industries
Tips
Handling Skills of Frequency Inverter Undervoltage
In order to protect the frequency inverter, when the bus voltage is too low, the frequency inverter will report an undervoltage fault and block the frequency inverter’s pulse output. This is an important and necessary method to protect the frequency inverter components from damage. This fault cannot be shielded either.
There is a bus voltage check mechanism inside the frequency inverter. When the measured value of the bus voltage is lower than a certain threshold, the frequency inverter will report an undervoltage fault.
There are many reasons for the undervoltage of the DC bus, which should be analyzed according to the actual situation. If you find the right root cause and then prescribe the right medicine, it can usually be solved.
1. The first is the influence from the incoming line voltage.
2. The second is the influence from the output end, that is, the inverter side.
3. Finally, there is a hardware problem.
Product Application
XCD-E7000 product application industry:
Processing centers, large complete sets of equipment, plastic machinery, textiles, printing, copper materials, printing and dyeing, packaging, woodworking machinery and other industries
Product detail pictures:
Related Product Guide:
Bear "Customer first, High quality first" in mind, we perform closely with our consumers and provide them with efficient and experienced services for Good Quality Vfd Drive Price - High Protection Universal Vector Inverter XCD-E7000 – LINGSHIDA, The product will supply to all over the world, such as: America, South Korea, Sri Lanka, We are your reliable partner in the international markets of our products. We focus on providing service for our clients as a key element in strengthening our long-term relationships. The continual availability of high grade products in combination with our excellent pre- and after-sales service ensures strong competitiveness in an increasingly globalized market. We are willing to cooperate with business friends from at home and abroad, to create a great future. Welcome to Visit our factory. Looking forward to have win-win cooperation with you.
By Meroy from Lesotho - 2018.03.03 13:09
We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
By Roberta from Lesotho - 2017.05.31 13:26